M125C
Leica M125C
Microscope Leica M125C General features:
- Zoom (zoom) 12.5:1;
- the Base zoom of 10x eyepieces and 1 objective lens: 8-100x;
- Working distance 61.5 mm;
- Maximum zoom range 5.1 – 800;
- corrected Apochromatic optics;
Maximum aperture NA = 0.288;
- the Maximum resolution with 2x lens 864 pairs of lines/mm;
the Optical scheme of the Abbe;
- Large set of different columns of 300 mm to 900 mm "D" shaped stands;
- Precision manual and motorized tables.
the the the the the the the the the the
|
Leica M125C |
Leica M165C |
Leica M205C and M205A |
Zoom |
12.5:1 |
16.5:1 |
20.5:1 |
Basic zoom range |
8x-100x |
7.3 x – 120x |
7.8 x – 160х |
Resolution: 1x lens; 2 lens; |
432 line pairs/mm 864 pairs of lines/mm |
453 line pairs/mm 960 line pairs/mm |
525 line pairs/mm 1050 line pairs/mm |
the Visible structure |
579 nm |
551 nm |
475 nm |
Maximum aperture |
0.288 |
0.302 |
0.35 |
Field of view on the sample diameter |
28.8 mm – 2.3 mm |
31.5 mm – 1.92 mm |
29.5 mm – 1.44 mm |
Optical design |
100 % apochromatic |
||
Coded |
Zoom and iris |
||
electrical |
2×1011 Ω/mm2 discharge time < 2 seconds from 1 000 V to 100 V |
safe to say that the Leica stereomicroscopes do not have to date competitors. In the Arsenal of these microscopes the largest increase, resolution and depth of focus. An additional major advantage of stereo microscopes is the lighting. Find out what are the benefits of microscopes Leica by sending us a request.
these microscopes perform a wide range of tasks and can be successfully applied in forensic, materials science, microelectronics and medicine.
Until the invention of a new optical scheme Gren all stereomicroscopes were performed according to the scheme of Ernst Abbe. More than a century all the eminent engineers of optical devices worked on the creation of the microscope, which would simultaneously maximize the magnification, resolution and depth of field, but each time was faced with the same problem: the higher the resolution of the microscope, the smaller the working distance and Vice versa.
was First implemented zoom (zoom) 20.5:1 on the Leica M205 stereomicroscope. In the same period has developed the latest patented optical system FusionOptics. This optical system enabled to increase the zoom range and increase the resolution to 1050 line pairs/mm, representing the size 476нм.
FusionOptics is a simple and ingenious solution to the construction of the optical system. Two fibre channel have different diameters. Left optical channel provides greater depth of field and the right channel provides the image with high resolution. When the operator looks into the two eyepiece at the same time, all the bumps, including deep risks, scratches, drops, remain in focus. Unfortunately, not always the camera can not convey the image that You see in the eyepieces.
Увеличение: | от 4 крат до 1280 крат |
Методы контрастирования: | Светлое поле, Темное поле, Поляризация, Флуоресценция |
Оптическая система: | 100 % апохроматический, CMO |